EFM Emerson ROC provides a configuration section to the Ignition Gateway that can be seen in the Configure section of the Ignition Gateway web UI. There is one configuration page - 'Settings'
![Figure 1. EFM Emerson ROC Module Configuration. Figure 1. EFM Emerson ROC Module Configuration.](/download/attachments/44893135/EFM-EMERSON-ROC_in_Configure_Section.png?version=1&modificationDate=1539299856000&api=v2)
Settings
The EFM Emerson ROC Settings configuration page allows user to create TLP Definitions as shown below:
![Figure 2. EFM Emerson ROC Settings -- TLP Definitions. Figure 2. EFM Emerson ROC Settings -- TLP Definitions.](/download/attachments/44893135/EFM-Emerson-ROC_TLP_Definitions.png?version=1&modificationDate=1539300385000&api=v2)
New TLP Definitions can be created by following the 'Create new TLP Definition' link as shown below:
![Figure 3. EFM Emerson ROC Settings -- New TLP Definition. Figure 3. EFM Emerson ROC Settings -- New TLP Definition.](/download/attachments/44893135/EFM-Emerson-ROC_New_TLP_Definition.png?version=1&modificationDate=1539300976000&api=v2)
Main Properties
- Name
- This is the friendly name of the TLP Definition being created
- CSV File
- Click the 'Browse' button to select CSV file for this TLP Definition
Click here to download the Cirrus Link default TLP and mapping files - Note these need to be thoroughly tested and reviewed in your application before they are put into production.
The downloaded zip file contains:
FB107-TLPs-V1_0.csv
FB107-Meter_Configuration_Mapping-V1_0.csv
FB107-Orifice_Turbine_Meter_Periodic_History_Mapping-V1_0.csv
ROC800-TLPs-V1_0.csv
ROC800-Meter_Configuration_Mapping-V1_0.csv
ROC800-Orifice_Turbine_Meter_Periodic_History_Mapping-V1_0.csv
UserProgram-TLPs-V1_0.csv
Emerson ROC Device Connection
Device connection for Emerson ROC module can be configured via OPC-UA SERVER.
![Figure 4 -- Emerson ROC Device Connection. Figure 4 -- Emerson ROC Device Connection.](/download/attachments/44893135/OPC-UA_Server_Devices.png?version=1&modificationDate=1539302929000&api=v2)
Selecting 'Devices' opens respective configuration page as shown below:
![](/download/attachments/44893135/EFM_Emerson-ROC-Devices.png?version=1&modificationDate=1539358611000&api=v2)
New Emerson ROC device can be created by following the 'Create new Device...' link and choosing 'EFM Emerson ROC' device as shown below:
![Figure 6. EFM Emerson ROC Device Connection -- Choose Device Type. Figure 6. EFM Emerson ROC Device Connection -- Choose Device Type.](/download/attachments/44893135/EFM_Emerson_ROC_Choose_Device_Type.png?version=1&modificationDate=1539355531000&api=v2)
This opens the 'New Device' configuration mage for EFM Emerson ROC Device:
![Figure 7. EFM Emerson ROC Device Connection -- Configuring New Device. Figure 7. EFM Emerson ROC Device Connection -- Configuring New Device.](/download/attachments/44893135/EFM_Emerson_ROC_New_Device.png?version=1&modificationDate=1539355738000&api=v2)
General
Connectivity
- Protocol Type
- Specific Protocol Type of the device
- Hostname
- Hostname or IP address of the device
- TCP Port
- ROC Unit Code
- Station Address Unit Code of the ROC unit
- ROC Group Code
- Station Address Group Code of the ROC unit
- Host Unit Code
- Station Address Unit Code of the host (this driver)
- Host Group Code
- Station Address Group Code of the host (this driver)
Records
- Alarm Scan Rate
- The rate in seconds that alarm records are scanned
- Set to -1 to disable alarm scanning (default)
- Event Scan Rate
- The rate in seconds that event records are scanned
- Set to -1 to disable event scanning (default)
- Minute History Scan Rate
- The rate in seconds that minute history records are scanned
- Set to -1 to disable minute history scanning (default)
- Periodic History Scan Rate
- The rate in seconds that periodic history records are scanned
- Set to -1 to disable periodic history scanning (default)
- Daily History Scan Rate
- The rate in seconds that daily history records are scanned
- Set to -1 to disable daily history scanning (default)
Sparkplug
- Group ID
- An ID representing a logical grouping of Edge Nodes and Devices
- Edge Node ID
- An ID representing an Edge or Network (EoN) Node
- Device ID
- An ID representing a Device
When all EFM Emerson ROC devices are configured, the Devices page will look as shown below:
![](/download/attachments/44893135/EFM-Emerson-ROC_Devices_Not_Configured.png?version=1&modificationDate=1539358897000&api=v2)
To finish configuring Emerson ROC and connect to physical devices, TLP definitions for each device need to be provided as described in the 'Specifying TLP Definitions for a Device' section of the EFM Emerson ROC Quickstart document. In short, the following three things need to be done:
- Specify TLP Definitions
- Provide TLP Templates by importing TLP-template CSV file
- Configure TLP Poll Groups by importing TLP-poll-group CSV file
When this is done, the 'Devices' configuration page will look as shown below with the 'Status' of each device set to 'Connected'.