You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Google Cloud Injector automatically creates a known set of folders containing tags for Injector Control and Injector Info.

The tables below describe these tags.

Google Cloud Injector Control

NameData TypeDescription
RefreshBooleanA writeable tag to request an Google Cloud Injector refresh. This will force all Edge Nodes to disconnect and reconnect resulting in the sending of NDEATH, NBIRTH and DBIRTH messages
Refresh RequiredBooleanA tag indicating that new tags have been identified by Google Cloud Injector and a refresh is required

Google Cloud Injector Info

NameData TypeDescription
Redundancy RoleStringThe redundancy configuration of the Ignition system that Google Cloud Injector is installed on. Options are Independent, Master and Backup
Redundancy StateStringThe redundancy status of the Ignition system that Google Cloud Injector is installed on. Options are Active or Cold
VersionString

The version of Google Cloud Injector currently installed