Now select the 'Settings' tab directly to the left of the 'Certificates' tab. Then click the 'Create new Azure IoT Edge Hub Setting...' link. This will open the following page.

Set the following parameters in the form (leave all others in their default state)

  • Main Section
    • Setting Name: Azure IoT EdgeAuthentication
  •  Authentication Section
    • Password: The Connection String associated with the 'Ignition' module you captured earlier in this tutorial.
    • CA Certificate File: The 'IoT Edge Device Root CA' created in the previous step

After the parameters are set, click the 'Save Changes' button at the bottom of the page. After doing so, you should see the following.

Image Added

If everything went well, you should also see 'Connected' under the Status column. Note it may take a couple of seconds to switch to a Connected status.

Info

If the Status does not show connected, browse to the Ignition 'Status → Logs' page to see any errors that may provide clues as to why the connection failed.