You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 7
Next »
The Cirrus Link default TLP Definitions and EFM Mapping files can be used as a starting point for configuring the EFM Emerson ROC module.
Once you have customized your configurations, you will likely encounter some issues and the following logged errors should give you clues on where to focus to resolve these issues.
Logger: com.cirruslink.emersonroc.EmersonRocDriver
Errors thrown:
['M-205' 10.0.40.169:4000] No Orifice meter configuration found at logical number 2
['M-205' 10.0.40.169:4000] No Orifice meter configuration found at logical number 3
Logger: com.cirruslink.emersonroc.protocol.model.opcode.OpCodeDataContainer
Errors thrown:
Failed to parse TLPs for pointType=7 and parameterNumber=178. Enable 'TRACE' for details.
Failed to parse out TLP Array. Enable 'DEBUG' for details.
Logger: com.cirruslink.emersonroc.protocol.model.point.DynamicPointTypeParameter
Errors thrown:
Invalid length: 4 for DataType: UINT16 - changing to default length: 2
Invalid length: 1 for DataType: FL - changing to default length: 4
Invalid length: 5 for DataType: UINT32 - changing to default length: 4