This opens the 'New Device' configuration mage for ABB Totalflow Device:

General

  • Name
    • Device name
  • Description
    • Device description
  • Enabled
    • Device enabled

Connectivity

  • Hostname
    • Hostname or IP address of the device
  • TCP Port
    • TCP Port of the device.
  • Socket Timeout
    • TCP socket operation (i.e. connect and read) timeout in seconds. A timeout of zero is interpreted as an infinite timeout. To use system default, set to -1.
  • Connection Type
    • Connection type selector. Either maintain one connection or establish new connection per each transaction. The ON_DEMAND option is recommended.
      • PERSISTENT - The ABB Totalflow driver keeps a TCP connection open and this connection is being shared by all polling threads.
      • ON DEMAND - A TCP connection is opened by each polling thread when it needs to poll and closed upon completion. Note that ABB Totalflow device still allows only one connection at a time.
  • Enable auto-discovery
    • Enables ABB Totalflow driver to run application auto-discovery at startup and re-configuration.

DB2 Protocol

  • Station ID
    • Station ID of this ABB Totalflow device
  • Keep Alive
    • Time interval (in seconds) between 'keep-alive' polls that may be required to maintain PERSISTENT connection if ABB Totalflow device is configured to disconnect on inactivity. To disable 'keep-alive' polls, set to 0. 
  • Host Timeout
    • Timeout (in milliseconds) to wait for a reply from the host. The default value is 3000 milliseconds.
  • Poll EOT Timeout
    • Time (in milliseconds) to wait to ensure there are no more packets to receive. The default value is 700 milliseconds.
  • Auto-Discovery EOT timeout
    • Time (in milliseconds) to wait to ensure there are no more packets to receive during auto-discovery. The default value is 2000 milliseconds. 
  • Number Retries
    • Number of retries if DB2 request is NAKed.
  • Supervisory Frames
    • Number of DB2 supervisory frames.
  • Password
    • DB2 Protocol Security Code. If device is set with default security code of 0000, leave blank.
  • Add All Array-Register Definitions
    • Automatically add all the Array-Register definitions configured within the ABB Totoalflow driver module.

RBAC

  • RBAC Enabled
    • A flag indicating that Role-Based Access Control (RBAC) is enabled on the device and therefore the X_RBAC frame needs to be included in the DB2 request message.
  • Operator ID
    • Operator ID.  If RBAC is not enabled on the device, leave blank.
  • Password
    • Operator password. If RBAC is enabled on the device, leave blank.