ABB Totalflow provides a configuration section to the Ignition Gateway that can be seen in the Configure section of the Ignition Gateway web UI. There is one configuration page - EFM ABB TOTALFLOW → Settings. The page contains two tabs: Array-Register Definitions and EFM Mappings.

Support Files

The Cirrus Link default Array-Register Definitions and EFM Mapping files can be used as a starting point for configuring the EFM ABB Totalflow module.

Download Array-Register Definitions zip file here

Download Meter Periodic Mapper CSV file here

(Note these need to be thoroughly tested and reviewed in your application before they are put into production)

Array-Register Definitions

The first tab contains settings for creating sets of Array-Register Definitions:

New Array-Register Definitions can be created by following the 'Create new Array-Register Definition' link as shown below:

Main Properties

Totalflow Applications Definitions

The Totalflow Applications Definitions provide the driver with application information such as:

The  Totalflow Applications Definitions tab allows user to add new application definitions or modified existing ones that driver was build with. The tab shows all uploaded application definitions files as shown below:

A new Totalflow Applications Definition can be added by clicking on the "Create new Totalflow Applications Definition..." link.

Main Properties

EFM Mappings

The EFM Mappings are used for publishing EFM Records representing Daily and Periodic History entries that are polled from a device.

Periodic Mappings

The periodic mapping files are used for building up EFM Daily and Periodic History Records.  They define column names for record's fields. 

Click here for more details on the content of these mapping files.

The Periodic Mappings tab shows all uploaded Periodic Mapping files as shown below:

A new Periodic Mapping can be added by clicking on the "Create new Periodic Mapping..." link.

Main Properties


ABB Totalflow Device Connection

Device connection for ABB Totalflow module can be configured via OPC-UA SERVER.  Selecting OPC-UA SERVER → Devices opens respective configuration page as shown below:

New ABB Totalflow device can be created by following the 'Create new Device...' link and choosing 'EFM ABB Totalflow' device as shown below:

This opens the 'New Device' configuration mage for ABB Totalflow Device:

General

Device

Connectivity

Auto Setup

Import Policies

DB2 Protocol

RBAC

Date/Time

Records

Records Signature

Sparkplug

Miscellaneous

When all ABB Totalflow devices are configured, the Devices page will look as shown below:

To finish configuring ABB Totalflow device, the following four things (as detailed in EFM ABB Totalflow Quickstart document) need to be done:

When this is done, the 'Devices' configuration page will show the 'Status' for each device changed from 'Connected' to the 'Polling' state.