When selecting a tab on a Cirrus Link Module and the Ignition UI shows the error below, the most likely cause is that a property referenced on that tab is no longer available. This could be due to a migration issue after an upgrade or because configuration items were modified using the scripting APIs.
In the logs you will see an error from the "org.apache.wicket.DefaultExceptionMapper" logger similar to the one shown below:
Expanding the logger error will show the internal error:
Scrolling to the "Caused by:" section will give additional details.
In this case, the Transmission History Store with ID 16, that is referenced by a Transmitter configuration, no longer exists.
Once you have identified the problem, you can use the script commands to find and update the problematic configuration, for example
# Read Transmitter Config savedTransmitters = system.cirruslink.transmission.readConfig("Transmitters") for config in savedTransmitters: if config["HistoryStoreId"] == 16: transmitterId = config["Id"] # Update config with valid history store ID myHistoryStoreId = 1 transmitterProps = {} transmitterProps["HistoryStoreId"] = myHistoryStorId system.cirruslink.transmission.updateConfig(“Transmitters”, transmitterId, “MergeOverwrite”, transmitterProps)