EFM Emerson ROC provides a configuration section to the Ignition Gateway that can be seen in the Configure section of the Ignition Gateway web UI. There is one configuration page - 'Settings'

Figure 1. EFM Emerson ROC Module Configuration.

Settings

The EFM Emerson ROC Settings configuration page allows user to create TLP Definitions as shown below:

Figure 2. EFM Emerson ROC Settings -- TLP Definitions.

New TLP Definitions can be created by following the 'Create new TLP Definition' link as shown below:

Figure 3. EFM Emerson ROC Settings -- New TLP Definition.

Main Properties

  • Name
    • This is the friendly name of the TLP Definition being created
  • CSV File
    • Click the 'Browse' button to select CSV file for this TLP Definition

Click here to download the Cirrus Link default TLP files - Note these need to be thoroughly tested and reviewed in your application before they are put into production.

Emerson ROC Device Connection

Device connection for Emerson ROC module can be configured via OPC-UA SERVER.

Figure 4 -- Emerson ROC Device Connection.

Selecting 'Devices' opens respective configuration page as shown below:

New Emerson ROC device can be created by following the 'Create new Device...' link and choosing 'EFM Emerson ROC' device as shown below:

Figure 6. EFM Emerson ROC Device Connection -- Choose Device Type.

This opens the 'New Device' configuration mage for EFM Emerson ROC Device:

Figure 7. EFM Emerson ROC Device Connection -- Configuring New Device.

General

  • Name
    • Device name
  • Description
    • Device description
  • Enabled
    • Device enabled

Connectivity

  • Protocol Type
    • Specific Protocol Type of the device
      • ROC
      • ROC_PLUS
  • Hostname
    • Hostname or IP address of the device
  • TCP Port
    • TCP Port of the device.
  • ROC Unit Code
    • Station Address Unit Code of the ROC unit
  • ROC Group Code
    • Station Address Group Code of the ROC unit
  • Host Unit Code
    • Station Address Unit Code of the host (this driver)
  • Host Group Code
    • Station Address Group Code of the host (this driver)

Records

  • Alarm Scan Rate
    • The rate in seconds that alarm records are scanned
    • Set to -1 to disable alarm scanning (default)
  • Event Scan Rate
    • The rate in seconds that event records are scanned
    • Set to -1 to disable event scanning (default)
  • Minute History Scan Rate
    • The rate in seconds that minute history records are scanned
    • Set to -1 to disable minute history scanning (default)
  • Periodic History Scan Rate
    • The rate in seconds that periodic history records are scanned
    • Set to -1 to disable periodic history scanning (default)
  • Daily History Scan Rate
    • The rate in seconds that daily history records are scanned
    • Set to -1 to disable daily history scanning (default)

Sparkplug

  • Group ID
    • An ID representing a logical grouping of Edge Nodes and Devices
  • Edge Node ID
    • An ID representing an Edge or Network (EoN) Node
  • Device ID
    • An ID representing a Device

When all EFM Emerson ROC devices are configured, the Devices page will look as shown below:

To finish configuring Emerson ROC and connect to physical devices, TLP definitions for each device need to be provided as described in the 'Specifying TLP Definitions for a Device' section of the EFM Emerson ROC Quickstart document. In short, the following three things need to be done:

  • Specify TLP Definitions 
  • Provide TLP Templates by importing TLP-template CSV file
  • Configure TLP Poll Groups by importing TLP-poll-group CSV file

When this is done, the 'Devices' configuration page will look as shown below with the 'Status' of each device set to 'Connected'.