  • Network paths
    •  It may make sense to have edge nodes support multiple network paths to the MQTT servers.  For example, Ethernet, cellular, and satellite could all exist as supported network paths on a single Edge gateway.  This will help ensure additional reliability by supporting failover of networks.
  • Primary Ignition and Primary Ignition backup placement
    • This tutorial was created by modeling this exact environment using Amazon AWS EC2 instances in the cloud.  Reliability could be improved by putting Ignition Primary and Ignition Primary Backup in different AWS availability zones or even different AWS regions.  This would allow the primary Ignition with MQTT Distributor and MQTT Engine to continue to operate even in the case of AWS failures.  In the case of on premises installations of Ignition these could be placed in different physical locations and/or on secondary networks.
  • MQTT Servers
  • History enablement in MQTT Transmission
    • MQTT Transmission supports caching of data in the case that it can not establish a connection to any of the configured MQTT Servers.  Once a connection is reestablished, it will begin reporting and flush the stored historical values to prevent data loss in catastrophic failures.

...

The following configuration shows all of the redundancy settings that were used in setting this environment up using Amazon's AWS EC2 instances (virtual machines).  The configuration will vary based on your network configuration.  Additional Ignition redundancy resources can be found at the following links:https://docs.inductiveautomation.com/display/DOC/Setting+Up+Redundancy
https://support.inductiveautomation.com/usermanuals/ignition/index.html?redundancy_settings.htm
here Ignition Setting Up Redundancy

Note
The Ignition Standby Activity Level, which is how the node operates when it is not the active node, has no impact on the MQTT modules. For the purposes of the tutorial we have set the Standby Activity to 'Warm'


Ignition Primary

  • Select Redundancy on the left navigation bar. Then set the Mode to 'Master' and set the Standby Activity left to 'Warm' as shown below.

...