EFM Emerson ROC provides a configuration section to the Ignition Gateway that can be seen in the Configure section of the Ignition Gateway web UI. There is one configuration page - 'Settings'

Figure 1. EFM Emerson ROC Module Configuration.Image Modified

Settings

The EFM Emerson ROC Settings configuration page allows user to create TLP Definitions as shown below:

Figure 2. EFM Emerson ROC Settings -- TLP Definitions.Image Modified

New TLP Definitions can be created by following the 'Create new TLP Definition' link as shown below:

Figure 3. EFM Emerson ROC Settings -- New TLP Definition.Image Modified

Main Properties

  • Name
    • This is the friendly name of the TLP Definition being created
  • CSV File
    • Click the 'Browse' button to select CSV file for this TLP Definition

Click here to download the Cirrus Link default TLP and mapping files - Note these need to be thoroughly tested and reviewed in your application before they are put into production.

The downloaded zip file contains:

    

     FB107-TLPs-V1_0.csv

     FB107-Meter_Configuration_Mapping-V1_0.csv

     FB107-Orifice_Turbine_Meter_Periodic_History_Mapping-V1_0.csv


     ROC800-TLPs-V1_0.csv

     ROC800-Meter_Configuration_Mapping-V1_0.csv

     ROC800-Orifice_Turbine_Meter_Periodic_History_Mapping-V1_0.csv


     UserProgram-TLPs-V1_0.csv

Emerson ROC Device Connection

Device connection for Emerson ROC module can be configured via OPC-UA SERVER.

Figure 4 -- Emerson ROC Device Connection.Image Modified

Selecting 'Devices' opens respective configuration page as shown below:

Figure 5. EFM Emerson ROC Device Connection. Devices.Image RemovedImage Added

New Emerson ROC device can be created by following the 'Create new Device...' link and choosing 'EFM Emerson ROC' device as shown below:

Figure 6. EFM Emerson ROC Device Connection -- Choose Device Type.Image Modified

This opens the 'New Device' configuration mage for EFM Emerson ROC Device:

Figure 7. EFM Emerson ROC Device Connection -- Configuring New Device.Image Modified

General

  • Name
    • Device name
  • Description
    • Device description
  • Enabled
    • Device enabled

...

  • Group ID
    • An ID representing a logical grouping of Edge Nodes and Devices
  • Edge Node ID
    • An ID representing an Edge or Network (EoN) Node
  • Device ID
    • An ID representing a Device

When all EFM Emerson ROC devices are configured, the Devices page will look as shown below:

Image Added

To finish configuring Emerson ROC and connect to physical devices, TLP definitions for each device need to be provided as described in the 'Specifying TLP Definitions for a Device' section of the EFM Emerson ROC Quickstart document. In short, the following three things need to be done:

  • Specify TLP Definitions 
  • Provide TLP Templates by importing TLP-template CSV file
  • Configure TLP Poll Groups by importing TLP-poll-group CSV file

When this is done, the 'Devices' configuration page will look as shown below with the 'Status' of each device set to 'Connected'.

Image Added