Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

EFM Emerson ROC provides a configuration section to the Ignition Gateway that can be seen in the Configure section of the Ignition Gateway web UI. There is one configuration page - 'Settings'

Figure 1. EFM Emerson ROC Module Configuration.Image Modified

Settings

The EFM Emerson ROC Settings configuration page allows user to create TLP Definitions as shown below:

Figure 2. EFM Emerson ROC Settings -- TLP Definitions.Image Modified

New TLP Definitions can be created by following the 'Create new TLP Definition' link as shown below:

Figure 3. EFM Emerson ROC Settings -- New TLP Definition.Image Modified

Main Properties

  • Name
    • This is the friendly name of the TLP Definition being created
  • CSV File
    • Click the 'Browse' button to select CSV file for this TLP Definition

Click here to download the Cirrus Link default TLP and mapping files - Note these need to be thoroughly tested and reviewed in your application before they are put into production.

The downloaded zip file contains:

    

     FB107-TLPs-V1_0.csv

     FB107-Meter_Configuration_Mapping-V1_0.csv

     FB107-Orifice_Turbine_Meter_Periodic_History_Mapping-V1_0.csv


     ROC800-TLPs-V1_0.csv

     ROC800-Meter_Configuration_Mapping-V1_0.csv

     ROC800-Orifice_Turbine_Meter_Periodic_History_Mapping-V1_0.csv


     UserProgram-TLPs-V1_0.csv

Emerson ROC Device Connection

Device connection for Emerson ROC module can be configured via OPC-UA SERVER.

Figure 4 -- Emerson ROC Device Connection.Image Modified

Selecting 'Devices' opens respective configuration page as shown below:

Image RemovedImage Added

New Emerson ROC device can be created by following the 'Create new Device...' link and choosing 'EFM Emerson ROC' device as shown below:

Figure 6. EFM Emerson ROC Device Connection -- Choose Device Type.Image Modified

This opens the 'New Device' configuration mage for EFM Emerson ROC Device:

Figure 7. EFM Emerson ROC Device Connection -- Configuring New Device.Image Modified

General

  • Name
    • Device name
  • Description
    • Device description
  • Enabled
    • Device enabled

...

  • Group ID
    • An ID representing a logical grouping of Edge Nodes and Devices
  • Edge Node ID
    • An ID representing an Edge or Network (EoN) Node
  • Device ID
    • An ID representing a Device

When all EFM Emerson ROC devices are configured, the Devices page will look as shown below:

Image Added

To finish configuring Emerson ROC and connect to physical devices, TLP definitions for each device need to be provided as described in the 'Specifying TLP Definitions for a Device' section of the EFM Emerson ROC Quickstart document. In short, the following three things need to be done:

  • Specify TLP Definitions 
  • Provide TLP Templates by importing TLP-template CSV file
  • Configure TLP Poll Groups by importing TLP-poll-group CSV file

When this is done, the 'Devices' configuration page will look as shown below with the 'Status' of each device set to 'Connected'.

Image Added