Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Prerequisites

  • Install IoT Bridge for Snowflake into your Azure account
    • Before being able to access the Virtual Machine you must have completed the installation process here.
  • Install an MQTT Server configured with a real signed TLS certificate


    Tip
    This quickstart guide uses the Chariot MQTT Server which can be installed as a free trial from the Azure Marketplace.

    Review the Chariot MQTT Server Configuration for details on how to upload the necessary certificates and keys for enabling SSL/TLS


    Note

    If you choose not to use Chariot MQTT Server, any Sparkplug compliant MQTT Server will work.

    Warning

    Azure IoT Hub is not Sparkplug compliant


    Warning

    AWS IoT Core has a message size limit of 128KB and will disconnect the client if it receives a message that exceeds this limit. If you have a large number of UDT definitions/instances and/or have very large UDTs, you will very likely hit this limit when sending your UDTs to AWS IoT Core. Review this document for ways to reduce the message size.





Summary

IoT Bridge for Snowflake (IBSNOW) is an application that connects to an MQTT Server (such as Chariot MQTT Server) and consumes MQTT Sparkplug messages from Edge devices.

When these messages are formatted as Sparkplug Templates, as defined in the Sparkplug Specification, the templates are used to create the data in Snowflake automatically with no additional coding or configuration.

Warning
If the messages do not use templates, they will be stored in a database table as unprocessed messages and additional work will be required to use this data in Snowflake.

Then multiple instances of these Templates generate the Assets and start to populate with real time data sent on change only, thus significantly reducing the amount of data being sent to the cloud.  For further details on Snowflake, refer to the documentation here. For further details on Eclipse Sparkplug, refer to the Eclipse Sparkplug resources.

This Quickstart document covers how IoT Bridge can be used to consume MQTT Sparkplug data and create and update data in Snowflake. This will show how to configure IoT Bridge as well as show how to use Inductive Automation's Ignition platform along with Cirrus Link's MQTT modules to publish device data to an MQTT Server. This data will ultimately be consumed by IoT Bridge to create and update the Snowflake components. This tutorial will use the Cirrus Link Chariot MQTT Server implementation. However, IBSNOW does work with any MQTT v3.1.1 compliant MQTT Server including Cirrus Link's MQTT Servers.

It is also important to note that Ignition in conjunction with Cirrus Link's MQTT Transmission module converts Ignition User Defined Types (UDTs) to Sparkplug Templates. This is done automatically by the MQTT Transmission module. So, much of this document will refer to UDTs rather than Sparkplug Templates since that is what they are in Ignition. More information on Inductive Automation's Ignition platform can be found here. Additional information on Cirrus Link's MQTT Transmission module can be found here.


Snowflake Setup

If you don't have a Snowflake account, open a Web Browser and go to https://www.snowflake.com. Follow the instructions there to start a free trial. After creating an account, log in to Snowflake via the Web Console. You should see something like what is shown below.

Create a new 'SQL Worksheet' by clicking the blue + button in the upper right hand corner of the window as shown below.

Copy and paste SQL Script 01 from Snowflake Setup Scripts into the center pane of the SQL Worksheet, click the drop down arrow next to the blue play button in the upper right corner of the window and click 'Run All' as shown below.

After doing so, you should see a message in the 'Results' pane denoting the SPARKPLUG_RAW table was created successfully as shown below.

Now, repeat the process for each of the following scripts in the Snowflake Setup Scripts in order. Each time, fully replace the contents of the SQL script with the new script and click the 'Run All' button after pasting each script. Make sure no errors are displayed in the Results window after running each script.

  • SQL Script 02 Expected Result: Stream NBIRTH_STREAM successfully created.

  • SQL Script 03 Expected Result: Function GENERATE_DEVICE_ASOF_VIEW_DDL successfully created.

  • SQL Script 04 Expected Result: Function CREATE_EDGE_NODE_SCHEMA successfully created.

  • SQL Script 05 Expected Result: Function CREATE_ALL_EDGE_NODE_SCHEMAS successfully created.

  • SQL Script 06 Expected Result: Statement executed successfully.

  • SQL Script 07 Expected Result: Statement executed successfully.

  • SQL Script 08 Expected Result: Statement executed successfully.


After all of the scripts have successfully executed, create a new user in Snowflake. This user will be used by IoT Bridge for Snowflake to push data into Snowflake. In the Snowflake Web UI, go to Admin → Users & Roles and then click '+ User' in the upper right hand corner. Give it a username of your choice and a secure password as shown below. For this example we're calling the user IBSNOW_INGEST so we know this user is for ingest purposes. See below for an example and then click 'Create User'.

In addition, the user must have a specific role to be able to stream data into Snowflake. Click the newly created user to see the following.

In the bottom of the center 'Granted Roles' pane you will see this user has no roles. Click 'Grant Role' to set up a new role. Then, select the 'CL_BRIDGE_PROCESS_RL' role and click 'Grant' as shown below.

After this has been done successfully you will see the role now associated with the new user as shown below.

Now an unencrypted key pair must be generated and uploaded to Snowflake. This will be used for authentication by the IoT Bridge for Snowflake application to push data to Snowflake via the Snowflake Streaming API.

Attach the generated unencrypted public key to the IBSNOW_INGEST user that we just created for Snowflake ingest purposes.

Tip

See this document for details on how to generate this unencrypted key and assign this to a user in your snowflake account: https://docs.snowflake.com/en/user-guide/key-pair-auth.

Note: The step "Configuring the Snowflake Client to User Key Pair Authentication" in the linked tutorial can be skipped.

Warning
The generated key MUST NOT be encrypted



IoT Bridge Setup

First you will need access to the Azure Virtual Machine via SSH. See this document for information on how to access the VM.

Configuring the Snowflake properties

Modify the file /opt/ibsnow/conf/ibsnow.properties file. Set the following:

  • mqtt_server_url
  • mqtt_server_name
    • Give it a meaningful name if desired
  • mqtt_username
    • The username for the MQTT connection if required
    • If using Chariot MQTT Server, the default username is 'admin'
  • mqtt_password
    • The password for the MQTT connection if required
    • If using Chariot MQTT Server, the default password is 'changeme'
  • primary_host_id
    • Set it to a text string such as 'IamHost'
  • snowflake_streaming_client_name
    • Some text string such as 'MY_CLIENT'
  • snowflake_streaming_table_name
    • This is the staged_sparkplug_raw_table created by the Snowflake setup in SQL Script 02
    • If the default Snowflake setup scripts were used, this is 'SPARKPLUG_RAW'
  • snowflake_notify_db_name
    • This is the cl_bridge_node_db created by the Snowflake setup in SQL Script 06
    • If the default Snowflake setup scripts were used, this is 'cl_bridge_node_db'
  • snowflake_notify_schema_name
  • snowflake_notify_warehouse_name
    • This is the cl_bridge_ingest_wh created by the Snowflake setup in SQL Script 07
    • If the default Snowflake setup scripts were used, this is 'cl_bridge_ingest_wh'

When complete, it should look similar to what is shown below.

Excerpt Include
CLD80:IBSNOW: Snowflake IoT Bridge properties configuration
CLD80:IBSNOW: Snowflake IoT Bridge properties configuration
nopaneltrue

Configuring the snowflake streaming profile

Now, modify the file /opt/ibsnow/conf/snowflake_streaming_profile.json file as described in Setting snowflake_streaming_profile configuration

When complete, it should look similar to what is shown below.

Excerpt Include
CLD80:IBSNOW: Setting snowflake_streaming_profile configuration
CLD80:IBSNOW: Setting snowflake_streaming_profile configuration
nopaneltrue


Now the service can be restarted to pick up the new configuration. Do so by running the following command.

sudo systemctl restart ibsnow

At this point, IBSNOW should connect to the MQTT Server and be ready to receive MQTT Sparkplug messages. Verify by running the following command.

tail -f /opt/ibsnow/log/wrapper.log

After doing so, you should see something similar to what is shown below. Note the last line is 'MQTT Client connected to ...'. That denotes we have successfully configured IBSNOW and properly provisioned MQTT Server.

Code Block
languagebash
INFO|7263/0||23-06-29 20:19:32|20:19:32.932 [Thread-2] INFO  org.eclipse.tahu.mqtt.TahuClient - IBSNOW-8bc00095-9265-41: Creating the MQTT Client to ssl://54.236.16.39:8883 on thread Thread-2
INFO|7263/0||23-06-29 20:19:33|20:19:33.275 [MQTT Call: IBSNOW-8bc00095-9265-41] INFO  org.eclipse.tahu.mqtt.TahuClient - IBSNOW-8bc00095-9265-41: connect with retry succeeded
INFO|7263/0||23-06-29 20:19:33|20:19:33.280 [MQTT Call: IBSNOW-8bc00095-9265-41] INFO  org.eclipse.tahu.mqtt.TahuClient - IBSNOW-8bc00095-9265-41: Connected to ssl://54.236.16.39:8883
INFO|7263/0||23-06-29 20:19:33|20:19:33.294 [MQTT Call: IBSNOW-8bc00095-9265-41] INFO  o.eclipse.tahu.host.TahuHostCallback - This is a offline STATE message from IamHost - correcting with new online STATE message
FINEST|7263/0||23-06-29 20:19:33|20:19:33.297 [MQTT Call: IBSNOW-8bc00095-9265-41] INFO  o.eclipse.tahu.host.TahuHostCallback - This is a offline STATE message from IamHost - correcting with new online STATE message
FINEST|7263/0||23-06-29 20:19:33|20:19:33.957 [Thread-2] INFO  org.eclipse.tahu.mqtt.TahuClient - IBSNOW-8bc00095-9265-41: MQTT Client connected to ssl://54.236.16.39:8883 on thread Thread-2


Edge Setup with Ignition and MQTT Transmission

Install Ignition and MQTT Transmission module

At this point IoT Bridge is configured and ready to receive data. To get data flowing into IBSNOW we'll set up Inductive Automation's Ignition platform along with the MQTT Transmission module from Cirrus Link.

Installation of Ignition is very straightforward following the instructions in the Installing and Upgrading Ignition guide.

With Ignition installed, the Cirrus Link MQTT Transmission module must be installed as a plugin to Ignition. Follow the instructions in our Module Installation guide

Import UDTs and tags

Launch the Ignition Designer to connect to your Ignition instance.

Once it is launched, navigate to the 'default' tag provider in the Tag Browser, expand the tag tree to see the automatically created tags as shown below and delete tags Example Tag and MQTT Quickstart.

From the Designer import these tags IBSNOW_Quickstart_tags.json to MQTT Tags > PLC 1 to create a UDT Definition and instance.

Tip
Review the Ignition Exporting and Importing Tags document if needed

You can view the imported UDT Definition and instance in the tag browser:

At this point, our tags are configured. A UDT definition will map to a model in Snowflake and UDT instances in Ignition will map to Snowflake.

But, before this will happen we need to point MQTT Transmission to the Chariot MQTT Server. To do so, browse back to the Ignition Gateway Web UI and select MQTT Transmission → Settings from the left navigation panel.

Select the 'Transmitters' tab as shown below.

Now click the 'edit' button to the right of the 'Example Transmitter'. Scroll down to the 'Convert UDTs' option and uncheck it as shown below. This will also un-grey the 'Publish UDT Definitions' option. Leave it selected as shown below.

Now switch to the 'Servers' and 'Settings' tab. Delete the existing 'Chariot SCADA' pre-seeded MQTT Server Definition. Then create a new one with the following configuration.

  • Name
    • Chariot MQTT Server
  • URL
  • Username
    • Your username for the Chariot MQTT Server connection
    • If using Chariot MQTT Server, the default username is 'admin'
  • Password
    • Your password for the Chariot MQTT Server connection
    • If using Chariot MQTT Server, the default password is 'changeme'

When complete, you should see something similar to the following. However, the 'Connected' state should show '1 of 1' if everything was configured properly.


At this point, data should be flowing into Snowflake.

By tailing the log in IBSNOW you should see something similar to what is shown below which shows IBSNOW receiving the messages published from Ignition/MQTT Transmission.

When IBSNOW receives the Sparkplug MQTT messages, it creates and updates asset models and assets in Snowflake. The log below is also a useful debugging tool if things don't appear to work as they should.


Code Block
languagebash
titleSuccessful Insert
FINEST|199857/0||23-04-21 15:46:22|15:46:22.951 [TahuHostCallback--3deac7a5] INFO  o.e.tahu.host.TahuPayloadHandler - Handling NBIRTH from My MQTT Group/Edge Node ee38b1
FINEST|199857/0||23-04-21 15:46:22|15:46:22.953 [TahuHostCallback--3deac7a5] INFO  o.e.t.host.manager.SparkplugEdgeNode - Edge Node My MQTT Group/Edge Node ee38b1 set online at Fri Apr 21 15:46:22 UTC 2023
FINEST|199857/0||23-04-21 15:46:23|15:46:23.072 [TahuHostCallback--3deac7a5] INFO  o.e.tahu.host.TahuPayloadHandler - Handling DBIRTH from My MQTT Group/Edge Node ee38b1/PLC 1
FINEST|199857/0||23-04-21 15:46:23|15:46:23.075 [TahuHostCallback--3deac7a5] INFO  o.e.t.host.manager.SparkplugDevice - Device My MQTT Group/Edge Node ee38b1/PLC 1 set online at Fri Apr 21 15:46:22 UTC 2023
FINEST|199857/0||23-04-21 15:46:23|15:46:23.759 [ingest-flush-thread] INFO  n.s.i.s.internal.FlushService - [SF_INGEST] buildAndUpload task added for client=MY_CLIENT, blob=2023/4/21/15/46/rth2hb_eSKU3AAtxudYKnPFztPjrokzP29ZXzv5JFbbj0YUnqUUCC_1049_48_1.bdec, buildUploadWorkers stats=java.util.concurrent.ThreadPoolExecutor@32321763[Running, pool size = 2, active threads = 1, queued tasks = 0, completed tasks = 1]
FINEST|199857/0||23-04-21 15:46:23|15:46:23.774 [ingest-build-upload-thread-1] INFO  n.s.i.i.a.h.io.compress.CodecPool - Got brand-new compressor [.gz]
FINEST|199857/0||23-04-21 15:46:23|15:46:23.822 [ingest-build-upload-thread-1] INFO  n.s.i.streaming.internal.BlobBuilder - [SF_INGEST] Finish building chunk in blob=2023/4/21/15/46/rth2hb_eSKU3AAtxudYKnPFztPjrokzP29ZXzv5JFbbj0YUnqUUCC_1049_48_1.bdec, table=CL_BRIDGE_STAGE_DB.STAGE_DB.SPARKPLUG_RAW, rowCount=2, startOffset=0, uncompressedSize=5888, compressedChunkLength=5872, encryptedCompressedSize=5888, bdecVersion=THREE
FINEST|199857/0||23-04-21 15:46:23|15:46:23.839 [ingest-build-upload-thread-1] INFO  n.s.i.s.internal.FlushService - [SF_INGEST] Start uploading file=2023/4/21/15/46/rth2hb_eSKU3AAtxudYKnPFztPjrokzP29ZXzv5JFbbj0YUnqUUCC_1049_48_1.bdec, size=5888
FINEST|199857/0||23-04-21 15:46:24|15:46:24.132 [ingest-build-upload-thread-1] INFO  n.s.i.s.internal.FlushService - [SF_INGEST] Finish uploading file=2023/4/21/15/46/rth2hb_eSKU3AAtxudYKnPFztPjrokzP29ZXzv5JFbbj0YUnqUUCC_1049_48_1.bdec, size=5888, timeInMillis=292
FINEST|199857/0||23-04-21 15:46:24|15:46:24.148 [ingest-register-thread] INFO  n.s.i.s.internal.RegisterService - [SF_INGEST] Start registering blobs in client=MY_CLIENT, totalBlobListSize=1, currentBlobListSize=1, idx=1
FINEST|199857/0||23-04-21 15:46:24|15:46:24.148 [ingest-register-thread] INFO  n.s.i.s.i.SnowflakeStreamingIngestClientInternal - [SF_INGEST] Register blob request preparing for blob=[2023/4/21/15/46/rth2hb_eSKU3AAtxudYKnPFztPjrokzP29ZXzv5JFbbj0YUnqUUCC_1049_48_1.bdec], client=MY_CLIENT, executionCount=0
FINEST|199857/0||23-04-21 15:46:24|15:46:24.301 [ingest-register-thread] INFO  n.s.i.s.i.SnowflakeStreamingIngestClientInternal - [SF_INGEST] Register blob request returned for blob=[2023/4/21/15/46/rth2hb_eSKU3AAtxudYKnPFztPjrokzP29ZXzv5JFbbj0YUnqUUCC_1049_48_1.bdec], client=MY_CLIENT, executionCount=0


Data will also be visible in Snowflake at this point. See below for an example. By changing data values in the UDT tags in Ignition DDATA Sparkplug messages will be produced. Every time the Edge Node connects, it will produce NBIRTH and DBIRTH messages. All of these will now appear in Snowflake with their values, timestamps, and qualities

Additional Resources