EFM Emerson ROC provides a configuration section to the Ignition Gateway and this can be seen in the left side menu bar of the Ignition Gateway web UI. 


Warning

Once TLP Definitions and EFM Mappings have been configured, the following additional steps are required to get all data available from a

...

ROC into Ignition:

  • Create a device connection
  • Specify the subset of TLP definitions that this specific ROC uses
  • Create TLP Template(s) which define groups of TLPs should be polled as a logical group
  • Create TLP Poll Group(s) which specify the logical parameters associated with a given TLP Template

The configuration options for each of the two tabs - TLP Definitions and EFM Mappings are detailed below. 

...

  • Name

    • This is the friendly name of the Periodic Mapping being created

  • CSV File

    • Click the 'Browse' button to select CSV file for this Periodic Mapping

To finish configuring Emerson ROC device, the following three things (as detailed in EFM Emerson ROC Quickstart document) need to be done:

  • Specify TLP Definitions (only if the "Add All TLP Definitions" was not enabled)
  • Provide TLP Templates by importing TLP-template CSV file
  • Configure TLP Poll Groups by importing TLP-poll-group CSV file

When this is done, the 'Devices' configuration page will show the 'Status' of each device set to 'Connected'.