Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

File formats described include:

...

  • Array-Register Templates

      ...

      ...

      Anchor

      ...

      TotalflowApplicationsDefinitions

      ...

      ple INI-backed_ArrayRegisterTemplates.csv file is an example of s

      ...

      The Free-Form_ArrayRegisterTemplates.csv file is a

      TotalflowApplicationsDefinitions
      Global Totalflow Applications Definitions

      An example of the Totalflow Application Definitions file can be found here: TotalflowApplicationsDefinitions.csv

      These mappings are CSV files with the following values:

      • Enumeration number
      • Name
      • Type
      • An optional flag (SU) that indicates that this is a 'Selectable Unit' application
      • Part number(s)

      Below is the file example:

      4, AGA3 Tube App,TUBE,, 2100779, 2100780, 2101305, 2101306, 2103845, 2100905,2100906, 2101786, 2101787, 2102418, 2103155
      5, AGA7 Tube App, TUBE, , 2100781, 2101307
      7, Trend, SYSTEM,, 2100787, 2101309
      20, SU Gas Orifice Tube App, TUBE, SU, 2100877, 2101426, 2102078, 2103741, 2104483, 2104484, 2104485, 2104508, 2104509
      21, SU Turbine Tube App,TUBE,SU,2100878,2102079,2103262, 2103742,2104486
      100, Simulated I/O, SIM, , 2101301

      ...

      EFM Periodic Mapping Files

      Tip
      The Cirrus Link default EFM Periodic Mapping file can be can be used as a reference point for configuring the EFM ABB Totalflow module.

      ...

      # arrayNum, appEnum, offset, data type, description, column name, enabled
      250,4|20,6,FLOAT,Average Differential Pressure,dp_avg,enabled
      250,5|21,6,FLOAT,Pulse Counts,pulses,enabled
      250,,10,FLOAT,Average Static Pressure,sp_avg,enabled
      250,,14,FLOAT,Average Temperature,temp_avg,enabled
      250,5|21,18,FLOAT,Uncorrected Volume,raw_vol,enabled
      250,,22,FLOAT,Volume,volume,enabled
      250,,26,FLOAT,Heating Value,heating_value,enabled
      250,,30,UINT16,Flow Time,flo,enabled
      250,,32,UINT16,Period Time,flo_rate,enabled


      Anchor
      ArrayRegister
      ArrayRegister
      Array-Register Templates

      Anchor
      INIArrayRegister
      INIArrayRegister
      INI Backed Array-Register Templates

      INI-backed_ArrayRegisterTemplates.csv file example

      Custom AGA3 Tube App[4_2101306]!
      3,0,Static Pressure,enabled
      3,3,Temperature,enabled
      3,17,Ft for NX19 Fpv,enabled
      3,18,Fp for NX19 Fpv,enabled
      3,19,Heating Value at Tb and Pb,enabled
      3,20,Real Relative Density at Tb and Pb,enabled
      3,21,N2,enabled
      3,22,CO2,enabled
      3,23,H2S,enabled
      3,24,H2O,enabled
      3,25,Helium,enabled
      3,26,Methane,enabled
      3,27,Ethane,enabled
      3,28,Propane,enabled
      3,29,N-Butane,enabled
      3,30,I-Butane,enabled
      3,31,N-Pentane,enabled
      3,32,I-Pentane,enabled
      3,33,N-Hexane,enabled
      3,34,N-Heptane,enabled
      3,35,N-Octane,enabled
      3,36,N-Nonane,enabled
      3,37,N-Decane,enabled
      3,38,Oxygen,enabled
      3,39,Carbon Monoxide,enabled
      3,40,Hydrogen,enabled
      3,41,Argon,enabled
      3,71,Energy,enabled
      3,72,Energy 3_72,enabled
      3,73,Energy Rate,enabled
      3,84,Energy 3_84,enabled
      7,0,Diff Pressure,enabled
      7,19,Flow Rate,enabled
      7,20,Volume,enabled
      7,21,Volume 7_21,enabled
      7,22,Volume 7_22,enabled
      7,23,Volume 7_23,enabled
      7,62,Energy 7_62,enabled
      7,68,Mass Rate,enabled
      7,69,Mass,enabled
      7,70,Mass 7_70,enabled
      7,72,Mass 7_72,enabled
      7,73,Mass 7_73,enabled

      Anchor
      FreeformArrayRegister
      FreeformArrayRegister
      Free Form Array-Register Templates

      Free-Form_ArrayRegisterTemplates.csv file example

      Custom AGA3 Tube App[-1_-1]!
      3,0,Static Pressure,enabled,R/O,FLOAT,Current Values
      3,3,Temperature,enabled,R/O,FLOAT,Current Values
      3,17,Ft for NX19 Fpv,enabled,R/W,FLOAT,Fixed Analysis Data
      3,18,Fp for NX19 Fpv,enabled,R/W,FLOAT,Fixed Analysis Data
      3,19,Heating Value at Tb and Pb,enabled,R/W,FLOAT,Fixed Analysis Data
      3,20,Real Relative Density at Tb and Pb,enabled,R/W,FLOAT,Fixed Analysis Data
      3,21,N2,enabled,R/W,FLOAT,Fixed Analysis Data
      3,22,CO2,enabled,R/W,FLOAT,Fixed Analysis Data
      3,23,H2S,enabled,R/W,FLOAT,Fixed Analysis Data
      3,24,H2O,enabled,R/W,FLOAT,Fixed Analysis Data
      3,25,Helium,enabled,R/W,FLOAT,Fixed Analysis Data
      3,26,Methane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,27,Ethane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,28,Propane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,29,N-Butane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,30,I-Butane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,31,N-Pentane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,32,I-Pentane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,33,N-Hexane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,34,N-Heptane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,35,N-Octane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,36,N-Nonane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,37,N-Decane,enabled,R/W,FLOAT,Fixed Analysis Data
      3,38,Oxygen,enabled,R/W,FLOAT,Fixed Analysis Data
      3,39,Carbon Monoxide,enabled,R/W,FLOAT,Fixed Analysis Data
      3,40,Hydrogen,enabled,R/W,FLOAT,Fixed Analysis Data
      3,41,Argon,enabled,R/W,FLOAT,Fixed Analysis Data
      3,71,Energy,enabled,R/O,FLOAT,Current Values
      3,72,Energy 3_72,enabled,R/O,FLOAT,Current Values
      3,73,Energy Rate,enabled,R/O,FLOAT,Current Values
      3,84,Energy 3_84,enabled,R/O,FLOAT,Current Values
      7,0,Diff Pressure,enabled,R/O,FLOAT,Current Values
      7,19,Flow Rate,enabled,R/O,FLOAT,Current Values
      7,20,Volume,enabled,R/O,FLOAT,Current Values
      7,21,Volume 7_21,enabled,R/O,FLOAT,Current Values
      7,22,Volume 7_22,enabled,R/O,FLOAT,Current Values
      7,23,Volume 7_23,enabled,R/O,FLOAT,Current Values
      7,62,Energy 7_62,enabled,R/O,FLOAT,Current Values
      7,68,Mass Rate,enabled,R/O,FLOAT,Current Values
      7,69,Mass,enabled,R/O,FLOAT,Current Values
      7,70,Mass 7_70,enabled,R/O,FLOAT,Current Values
      7,72,Mass 7_72,enabled,R/O,FLOAT,Current Values
      7,73,Mass 7_73,enabled,R/O,FLOAT,Current Values