Note |
---|
The ‘Filters' are applied to the respective server(s) only. If connection is switched to another server within the same server set, filters are not applied and the required Sparkplug B subscriptions will be used. Ensure that any Access Control Lists (ACLs) configured on the server match the Group or Group/EdgeNode configured in the Namespace Filter |
Example 1 for the Sparkplug B namespace
...
Setting the Sparkplug B Default Namespace Filters for a Group ID of 'Edge2' will ensure that only this Group ID will be included in the MQTT Engine subscription.
Example 2 for Sparkplug B namespace
A system with one Edge Node configured with two Server connections - one using the Sparkplug B protobuf format and the other using the Sparkplug B JSON formats.
The Edge Node has two Transmitters, one using each server with unique Sparkplug Group IDs of "Group1JSON" and "Group1".
Setting the Sparkplug B Default Namespace Filters for a Group ID of 'Group1' will ensure that only this Group ID will be included in the MQTT Engine subscription and MQTT engine will never receive the JSON formatted Sparkplug B messages.
...