  • Enable auto-discovery
    • Enables ABB Totalflow driver to run application auto-discovery at startup and re-configuration.
  • Add All Totalflow Application Definitions
    • Automatically add all Totalflow Applications definitions configured within the ABB Totoalflow driver module.
  • Add All Array-Register Definitions
    • Automatically add all the Array-Register definitions configured within the ABB Totoalflow driver module.
  • Auto-Generate Templates and Poll Groups
    • Automatically generates default Array-Register templates and default poll group on startup and reconfiguration. Note that the driver will create a default Array-Register template for specific application type (enumeration ) if the following criteria are met
      • Polling is enabled in the 'Totalflow Applications Panel' for at least one of applications of this type.
      • There should not be no custom template(s) for this application type.    

Import Policies

  • Array-Register Template Import Policy
    • UPDATE - update existing Array-Register Templates
    • REPLACE - replace existing Array-Register Templates
  • Poll Group Import Policy
    • UPDATE - update existing poll groups
    • REPLACE - replace existing poll groups

DB2 Protocol

  • Station ID
    • Station ID of this ABB Totalflow device.
  • Keep Alive
    • Time interval (in seconds) between 'keep-alive' polls that may be required to maintain PERSISTENT connection if ABB Totalflow device is configured to disconnect on inactivity. To disable 'keep-alive' polls, set to 0. 
  • Host Timeout
    • Timeout (in milliseconds) to wait for a reply from the host. The default value is 3000 milliseconds.
  • Poll EOT Timeout
    • Time (in milliseconds) to wait to ensure there are no more packets to receive. The default value is 700 milliseconds.
  • Auto-Discovery EOT timeout
    • Time (in milliseconds) to wait to ensure there are no more packets to receive during auto-discovery. The default value is 2000 milliseconds. 
  • Number Retries
    • Number of retries if DB2 request is NAKed.
  • Supervisory Frames
    • Number of DB2 supervisory frames.
  • Password
    • DB2 Protocol Security Code. If device is set with default security code of 0000, leave blank.

...

  • RBAC Enabled
    • Enables Role-Based Access Control (RBAC) is enabled on the device and therefore the X_RBAC frame needs to be included in the DB2 request message.
  • Operator ID
    • Operator ID.  If RBAC is not enabled on the device, leave blank.
  • Password
    • Operator password. If RBAC is enabled on the device, leave blank.

Date/Time

  • Date Time Offset
    • The date time offset of the Totalflow device clock from the Ignition system running this driver in seconds.

Records

  • Alarm Source
    • Alarm source selector.

      • PERIODIC-HISTORY_RECORDS - alarms are obtained from Periodic History records.
      • ALARM_LOG_RECORDS - alarms are obtained form Alarm Log records.
  • Alarm Scan Rate
    • The rate in seconds that Alarm Log Records are scanned. Set to 0 to poll on notification from the 'Record Info' scanner. To disable Alarm polls, set to -1.
  • Event Scan Rate
    • The rate in seconds that Event Records are scanned. Set to 0 to poll on notification from the 'Record Info' scanner. To disable Event polls, set to -1. 
  • Periodic History Scan Rate
    • The rate in seconds that Periodic History Records are scanned. Set to 0 to poll on notification from the 'Record Info' scanner. To disable Periodic History polls, set to -1.
  • Daily History Scan Rate
    • The rate in seconds that Daily History Records are scanned. Set to 0 to poll on notification from the 'Record Info' scanner. To disable Daily History polls, set to -1.
  • Record Info Scan Rate
    • The rate in seconds for the 'Record Info Registers' (i.e. History, Event and Alarm record capacity, last sequence number, etc.) to be scanned.
      If new Event, History, or Alarm Log records are detected, respective poller(s) will be notified. To disable 'RecordInfo' polls, set to -1. Set to 0 for one-shot 'Record Info' poll.
  • Max. Records to Read
    • Maximum number of records to read in one poll.
  • Periodic Mapping
    • The mapping of Totalflow LOG_PERIOD and DAILY structures to Flowcal Meter Periodic Transactions.

...