  • Alarm Scan Rate
    • Set to 0 to indicate that alarms are required.
  • Event Scan Rate
    • Set to -1 to disable polling for Events.
    • If the 'Record Info Scan Rate' is set to -1, the 'Event Scan Rate' can be set to 0. With this setup, the EventPoller will not run on it own nor will it poll on notifications from the RecordInfoPoller. 
  • Periodic History Scan Rate
    • Set to a positive number to launch the PeriodicHistoryPoller with specified poll rate.
  • Daily History Scan Rate
    • Set to -1 to disable polling for Daily History records.
    • If the 'Record Info Scan Rate' is set to -1, the 'Daily History Scan Rate' can be set to 0. With this setup, the DailyHistoryPoller will not run on it own nor will it poll on notifications from the RecordInfoPoller. 
  • Record Info Scan Rate
    • Set to -1 to disable the RecordInfoPoller so that there will be no notifications to Alarm, Events and History pollers on any 'RecordInfo' change such as 'Last Record Sequence number Used', etc.

Image RemovedImage Added

The second way is to set Record Info scan rate and obtain alarms from Periodic History records on notifications from the 'Record Info' poller as shown below:

...