  • Enable auto-discovery
    • Enables ABB Totalflow driver to run application auto-discovery at startup and re-configuration.
  • Add All Array-Register Definitions
    • Automatically add all the Array-Register definitions configured within the ABB Totoalflow driver module.
  • Auto-Generate Templates and Poll Groups
    • Automatically generates default Array-Register templates and default poll group on startup and reconfiguration. Note that the driver will create a default Array-Register template will be generated for specific application type (enumeration ) if polling the following criteria are met
      • Polling is enabled
      (see
      • in the 'Totalflow Applications Panel'
      below)
      • for at least one of applications of this type.
      Another requirement for the default Array-Register template to be generated is that there
      • There should not be no
      any
      • custom template(s) for this application type.    

DB2 Protocol

  • Station ID
    • Station ID of this ABB Totalflow device.
  • Keep Alive
    • Time interval (in seconds) between 'keep-alive' polls that may be required to maintain PERSISTENT connection if ABB Totalflow device is configured to disconnect on inactivity. To disable 'keep-alive' polls, set to 0. 
  • Host Timeout
    • Timeout (in milliseconds) to wait for a reply from the host. The default value is 3000 milliseconds.
  • Poll EOT Timeout
    • Time (in milliseconds) to wait to ensure there are no more packets to receive. The default value is 700 milliseconds.
  • Auto-Discovery EOT timeout
    • Time (in milliseconds) to wait to ensure there are no more packets to receive during auto-discovery. The default value is 2000 milliseconds. 
  • Number Retries
    • Number of retries if DB2 request is NAKed.
  • Supervisory Frames
    • Number of DB2 supervisory frames.
  • Password
    • DB2 Protocol Security Code. If device is set with default security code of 0000, leave blank.

...

  • Review default Array-Register Templates generated based on provided Array-Register definitions per each Totalflow application enumeration obtained during auto-discovery. Note that default Array-Register Template entry will be generated for application enumeration only if at lease one of installed application of this type is enabled. Default Array-Register templates can be modified by either editing or by importing an Array-Regsiter template CSV file.

...