Anchor
CapacityWarning
CapacityWarning

Info
titleWarning

If using a large tag capacity it is highly recommended to test the system under load in a non-production environment on similar hardware and software that will be used in production. During testing is also important to get the system into a state where the store and forward cache becomes full before beginning to flush. This will ensure that the system is sized appropriately when deployed into a production environment. There are a number of factors involved in determining how large the tag capacity can be including but not limited to system resources such as CPU, RAM (especially when using 'In-Memory'), Disk IOPS (if using 'Disk-Backed'), the nominal tag change rate (e.g. number of tags changing per second in the system), the flush rate, bandwidth availability, whether flushing in order vs asynchronously, etc. Because of the complex interactions of these variables it is highly recommended to test in a controlled environment. Generally any capacity over 2,000,000 is considered large and should be tested before deploying to production.

...