Name | Description of value |
---|---|
EVENT_TIMESTAMP | The timestamp that the tag write using the security context was performed in the format YYYY-MM-DD HH:MM:SS:mmm |
ACTOR | For Set to "unknown" (Ignition 8.1.33 or lower - Set as "unknown"For ) Set to username (Ignition 8.1.34 or higher - Set to usernameand MQTT Engine 4.0.20 or higher) |
ACTOR_HOST | The originating host system gateway name |
ACTION | Set as "tag write" |
ACTION_TARGET | The tag path for the tag that is being written to |
ACTION_VALUE | The Qualified Value (value, quality, timestamp) for the tag write |
STATUS_CODE | Currently not used - set as "0" |
ORIGINATING_SYSTEM | The system generating the audit record - set as "MQTT Transmission:DCMD Write" |
ORIGINATING_CONTEXT | Currently not used - set as "0" |
...