Cirrus Link Modules for Ignition v3.4.4 - October 11, 2018
- AWS Injector
- Added support for enabling/disabling streams on a per stream basis and via a tag in Ignition
- Fixed gateway configuration navigation error with session token changes
- Azure Injector
- Replaced underlying Cirrus Link Sparkplug implementation with Eclipse Tahu implementation
- Added maximum message size support to limit message sizes per Azure IoT Hub requirements
- Fixed auto-reconnect issue when connection should be shut down
- Added checks to prevent multiple connect threads
- Added session token generation support with configurable token timeout
- Made reconnect support asynchronous
- Fixed possibility of accidental LWT from being published
- Added support for enabling/disabling streams on a per stream basis and via a tag in Ignition
- Removed duplicate protocols from protocol selector drop-down menu
- EFM Emerson ROC Driver
- MQTT Distributor
- Fixed ACL issue that resulted in invalid ACL rejections with spaces in an ACL topic
- Added configuration time ACL validation of ACLs to prevent configuration time errors
- MQTT Engine
- Replaced underlying Cirrus Link Sparkplug implementation with Eclipse Tahu implementation
- Added support for interfacing to MQTT Recorder and handling Sparkplug Records
- Added ability to enable/disable specific MQTT server settings
- Fixed potential deadlock issue when tags are updated while Ignition is starting
- Added ability to filter namespaces for specific MQTT server settings
- Fixed issue where tag permissions were being overwritten
- Fixed some internal concurrency issues
- Naming convention changes improvements to some online/offline info tags
- MQTT Recorder
- MQTT Remote Management (Agent/Manager)
- Replaced underlying Cirrus Link Sparkplug implementation with Eclipse Tahu implementation
- MQTT Transmission
- Replaced underlying Cirrus Link Sparkplug implementation with Eclipse Tahu implementation
- Added support for sending Sparkplug Records from MQTT Transmission
- Fixed edge case disconnect issue that could result in failed LWT publish on disconnect
- Fixed issue where UDT member tag quality may not be published correctly
- Added support for interfacing to Sparkplug Record providers such as the EFM Emerson ROC module
- Fixed issue where an Edge Node removal from the default transmitter tag tree could result in the Edge Node to being removed
- Fixed issue where if aliases were being used the tag name was still also sent
- Fixes to edge case with in order history flushing in conjunction with primary host id usage
- Fixed potential deadlock when rebirth occurs at the same time as tag change events
- Removed UDT tag properties being sent in DATA messages
- Web UI cleanup to shown fields in the Transmitter configuration list
- Opto22 groov EPIC and SNAPPAC
...