- Type
- The type of History Store with options of In-Memory and Disk-Backed
- Data stored in an In-Memory History Store will not be persisted across a module configuration change, module disable/enable, module restart or power loss.
- Data stored in a Disk-Backed History Store will persist across a module configuration change, module disable/enable, module restart or power loss.
- History Max Size
- The maximum number of megabytes history can use before dropping the data
- In-Memory History Store will use the Ignition Java Heap memory
- Default is 500
- History Max Age
- Maximum number of minutes to store history before dropping the data.
- Flush Quantity
- The maximum number of tags to publish in a single message upon reestablishing communication.
- Default 10,000
- Flush Period
- The period to wait in milliseconds between publishes when flushing messages upon reestablishing communication.
- Default 200
...
{"serverDuration": 101, "requestCorrelationId": "ff2bfd2fd593d223"}